Please select from the main topics below.
Throughout the FAQs, the TR-71wf, TR-72wf, TR-72wf-S(*) and TR-75wf are referred to by their series name, "TR-7wf Series". The TR-71nw, TR-72nw, TR-72nw-S(*) and TR-75nw are similarly referred to as the "TR-7nw Series". In general any of these products may simply be called "the device" or "the data logger".
* Successor model of -H type
The device can be used in any of the following three ways:
Depending on how you want to use the device, it is necessary to prepare certain environments for use.
By installing T&D Data Server, it is possible to change the recorded data auto-upload destination from T&D WebStorage Server to the intranet or your own server, where you can view the uploaded data.
This application is for use with mobile devices. When using T&D Thermo with the TR-7wf Series, it is possible to make all settings, recording start and data downloading operations directly from the mobile device. The downloaded data can be viewed in graph form on the mobile device or can be sent by attaching the data file to an e-mail.
In the case of the TR-7nw Series, T&D Thermo can be used to view data on the mobile device via T&D WebStorage Service.
This software enables all settings, recording start and data downloading operations to be carried out from a PC. Simply connect the device to a PC using a USB cable.
TR-7wf/nw for Windows : HOME > Support
http://www.tandd.com/redirect/software/tr-7wf_nw_for_windows
This versatile graph software allows the user to view and analyze data without worrying about the number of data files or the location of the saved data. The user can also specify search conditions, as well as, enter comments before saving data. This program is necessary if you wish to download data from our WebStorage Service.
T&D Graph : HOME > Support
http://www.tandd.com/redirect/software/tandd_graph
This is a server application which can receive and store recorded data uploaded automatically from the device. This can be used when you wish to auto upload recorded data to a server other than T&D WebStorage Service.
T&D Data Server : HOME > Support
http://www.tandd.com/redirect/software/tandd_data_server
The device can be placed in a variety of location depending on the purpose for recording data. We suggest placing it in environments which satisfy the following conditions.
The battery life varies depending upon the frequency of communication, LAN environment, ambient temperature, recording interval, and battery performance. In instances where the device will be left for long periods of time, make sure to periodically check the battery strength level or use the optional AC adaptor (AD-05A2 or AD-05C2).
Android: Android OS 2.2 or higher
iOS: iOS 7.1 or higher (iPhone / iPad / iPod touch)
The TR-7nw Series can be used in all areas and countries throughout the world.
The TR-7wf Series has been designed to comply with the following regulations and should not be used in any countries other than those in which either of these regulations are the standard.
For more details please contact the distributor from which you purchased the product.
Although the sensor element of the temperature sensor does not experience loss of precision due to use over time, due to external factors, such as build up of water, losses in precision will occur.
If over time you experience losses in measurement precision, we suggest the purchase of a new sensor.
The temperature-humidity sensors will with normal use experience losses in precision and sensitivity over time due to degradation. If the sensor is being used in a smoky or dusty environment, the surface of the sensor will accumulate impurities causing a further decrease in the sensor's performance.
Yes, it is possible to lengthen a cable by using our optional sensor extension cables.
There are two lengths of extension cables: 1m and 3m. Only one cable can be connected to a temperature sensor; and up to 3 cables can be connected to a temp/humidity sensor.
Please contact your local distributor for the purchase of these and all optional items.
1m | 3m | |
---|---|---|
Extension Cable Type | TR-5C10 | TR-1C30 |
Yes, fee-based comparative calibrations for both temperature and humidity are possible.
Please contact your local distributor for information about these services.
Wireless LAN ( TR-7wf Series only ) ON : Connected to the wireless network (Signal strength: 1 to 3 bars) BLINKING : Unable to connect to the wireless network OFF : Wireless LAN settings not made |
|
ON : Connected to the Internet BLINKING : Unable to connect to the Internet OFF : Auto-upload is set to "OFF". |
|
Displayed Measurement Channel | |
ON : Mobile Device Communication Possible ( TR-7wf Series only ) | |
ON : Wireless LAN Setup using WPS Possible ( TR-7wf Series only ) | |
ON : Wireless LAN or USB Communication in Progress | |
ON : Recording in Progress | |
ENDLESS : Upon reaching the logging capacity of 8,000 readings, the oldest data is overwritten and recording continues ONETIME : Upon reaching the logging capacity of 8,000 readings, recording automatically stops *Cannot be set or changed using buttons on the logger. The factory default setting is "ENDLESS". |
|
Amount of Recorded Data in Device | |
ON : Low Battery
When the battery power becomes even lower after the battery warning mark appears, the
auto-upload will stop * Please change the batteries as soon as you see this mark. |
|
Auto Upload Interval | |
Recording Interval |
Full Data: Upon reaching capacity of 8,000 readings in "ONETIME" mode, this message appears and recording automatically stops | |
Sensor Error: No sensor connected, improper connection, damaged, etc | |
Sleep Mode: If you take no action after a battery warning mark appears and auto-upload stops, the logger will enter sleep mode and stop all operations to protect data. All operations are stopped to protect data in sleep mode. * If the logger remains in sleep mode over one week without a change of batteries, all recorded data will be lost. |
To update the firmware it is necessary to connect the device to a PC using a USB cable.
It is possible to check for updates by looking at the Support Menu in the T&D Thermo application.
The current version can be checked by going to [Settings Table] under the T&D Thermo direct communication icon.
Updates are available at "App Store" or "Google Play Store".
Software updates are available as downloads from our T&D Website.
By using a web browser or our mobile device app (T&D Thermo) it is possible to take advantage of the following features:
View the most recent measurements as well as view data in graph form.
Check the battery level, make various settings such as warning, and start recording in remote places.
You can receive a warning notification by email when a set upper or lower limit is exceeded.
Up to 80,000 data readings can be stored for each device when the data has been sent to T&D WebStorage Service using the Auto-upload function.
When the data readings exceed 80,000, the oldest data is deleted and storage continues.
On the T&D WebStorage Graph, up to 15,000 (most recent) data readings can be viewed for each device.
By using T&D Graph, it is possible to access all stored 80,000 data readings.
For details, see Q4: What is the best way to analyze data?
When manually sending data which has been downloaded using T&D Thermo, up to 20MB of data can be stored in WebStorage.
This doesn't include recorded data which was sent using the Auto-upload function.
Yes, it is possible to use the device without using the T&D WebStorage Service.
When you wish to share data in the internal network instead of the T&D WebStorage Service, please use the T&D Data Server.
T&D Data Server :
http://www.tandd.com/software/TD_data_server.html
If you wish not to use the auto-upload feature, you can use the following methods to collect recorded data.
Our graph software "T&D Graph" makes it possible to carry out a variety of operations that are not possible with the web browser or mobile device.
To use the graph software a PC running Windows operating system is necessary.
The software can be downloaded free of charge from here.
T&D Graph : http://www.tandd.com/software/td_graph.html
It is possible when using a web browser to share data by creating a Read-Only account.
With a Read-Only account it is possible to view data but it is not possible to delete data or make any settings changes.
Visit T&D WebStorage Service, go to the [Account Management] menu and from [Read-Only ID Settings] an account can be created.
To have the warning monitoring function work properly it is necessary to make settings beforehand.
Warning settings can be made via T&D Thermo, TR-7wf/nw for Windows and/or your web browser.
When a warning is judged to have o ccurred, a warning report e-mail will be sent to the e-mail address you used at the time of registration.
If you are using a junk mail filter, make sure to allow e-mail to come from T&D WebStorage Service (domain: webstorage-service.com)
If the device's power does not come on, please check the following:
If after checking and trying the above the power still does not come on please contact the distributor where the product was purchased.
Please check the following:
If wireless LAN settings can not be done using WPS, please carry out the wireless LAN settings manually using T&D Thermo or TR-7wf/nw for Windows.
Users of TR-7wf/nw for Windows, please refer to the Help for that program.
Wireless LAN Settings Procedure for Users of "T&D Thermo":
If direct communication fails, see [How can I communicate directly with a mobile device?] and retry from step 1.
Direct communication with using T&D Thermo will differ depending upon what kind of OS you are using.
The first time it will take 30 seconds to a minute before the check mark comes on.
The first time it will take 30 seconds to a minute before the wireless LAN mark comes on.
If direct communication using T&D Thermo continually fails please check the following:
Please check the following:
If the wireless LAN icon does not appear on the device LCD display, it means that wireless LAN connection settings have not been completed. Please make proper settings.
If the wireless LAN icon is blinking on the device LCD display, it means that there is a connection failure between the device and the access point. Check the following:
There is a connection failure to the T&D WebStorage Service. Check the following:
Check to see if the WEB mark is being displayed on the LCD of the data logger.
If the antenna mark is not on, check the following.
The Auto-upload feature has been set to OFF. Please make necessary Auto-upload Interval settings and set to ON.
There is a connection failure to the T&D WebStorage Service. Check the following:
Please check the following:
Please make sure that the combination of User ID and Password are correct and match.
If you can't remember or have lost your password, please get a new one reissued at T&D WebStorage Service